/* bug.n -- tiling window management Copyright (c) 2010-2015 Joshua Fuhs, joten This program is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details. @license GNU General Public License version 3 ../LICENSE.md or @version 9.0.0 */ Manager_init() { Local doRestore Manager_setWindowBorders() Bar_getHeight() ; axes, dimensions, percentage, flipped, gapWidth Manager_layoutDirty := 0 ; New/closed windows, active changed, Manager_windowsDirty := 0 Manager_aMonitor := 1 doRestore := 0 If (Config_autoSaveSession = "ask") { MsgBox, 0x4, , Would you like to restore an auto-saved session? IfMsgBox Yes doRestore := 1 } Else If (Config_autoSaveSession = "auto") { doRestore := 1 } SysGet, Manager_monitorCount, MonitorCount Loop, % Manager_monitorCount { Monitor_init(A_Index, doRestore) } Bar_initCmdGui() If Not Config_showTaskBar Monitor_toggleTaskBar() Manager_focus := False Manager_hideShow := False Bar_hideTitleWndIds := "" Manager_allWndIds := "" Manager_managedWndIds := "" Manager_initial_sync(doRestore) Bar_updateStatus() Bar_updateTitle() Loop, % Manager_monitorCount { View_arrange(A_Index, Monitor_#%A_Index%_aView_#1) Bar_updateView(A_Index, Monitor_#%A_Index%_aView_#1) } Manager_registerShellHook() SetTimer, Manager_doMaintenance, %Config_maintenanceInterval% SetTimer, Bar_loop, %Config_readinInterval% } Manager_activateMonitor(i, d = 0) { Local aView, aWndHeight, aWndId, aWndWidth, aWndX, aWndY, v, wndId If (Manager_monitorCount > 1) { aView := Monitor_#%Manager_aMonitor%_aView_#1 aWndId := View_getActiveWindow(Manager_aMonitor, aView) If aWndId { WinGetPos, aWndX, aWndY, aWndWidth, aWndHeight, ahk_id %aWndId% If (Monitor_get(aWndX + aWndWidth / 2, aWndY + aWndHeight / 2) = Manager_aMonitor) View_#%Manager_aMonitor%_#%aView%_aWndId := aWndId } ;; Manually set the active monitor. If (i = 0) i := Manager_aMonitor Manager_aMonitor := Manager_loop(i, d, 1, Manager_monitorCount) v := Monitor_#%Manager_aMonitor%_aView_#1 wndId := View_#%Manager_aMonitor%_#%v%_aWndId If Not (wndId And WinExist("ahk_id" wndId)) { If View_#%Manager_aMonitor%_#%v%_wndIds wndId := SubStr(View_#%Manager_aMonitor%_#%v%_wndIds, 1, InStr(View_#%Manager_aMonitor%_#%v%_wndIds, ";") - 1) Else wndId := 0 } Debug_logMessage("DEBUG[1] Manager_activateMonitor: Manager_aMonitor: " Manager_aMonitor ", i: " i ", d: " d ", wndId: " wndId, 1) Manager_winActivate(wndId) } } Manager_applyRules(wndId, ByRef isManaged, ByRef m, ByRef tags, ByRef isFloating, ByRef isDecorated, ByRef hideTitle, ByRef action) { Local i, mouseX, mouseY, wndClass, wndHeight, wndTitle, wndWidth, wndX, wndY Local rule0, rule1, rule2, rule3, rule4, rule5, rule6, rule7, rule8, rule9, rule10 isManaged := True m := 0 tags := 0 isFloating := False isDecorated := False hideTitle := False action := "" WinGetClass, wndClass, ahk_id %wndId% WinGetTitle, wndTitle, ahk_id %wndId% WinGetPos, wndX, wndY, wndWidth, wndHeight, ahk_id %wndId% If (wndClass Or wndTitle) { Loop, % Config_ruleCount { ;; The rules are traversed in reverse order. i := Config_ruleCount - A_Index + 1 StringSplit, rule, Config_rule_#%i%, `; If RegExMatch(wndClass . ";" . wndTitle, rule1 . ";" . rule2) And (rule3 = "" Or %rule3%(wndId)) { isManaged := rule4 m := rule5 tags := rule6 isFloating := rule7 isDecorated := rule8 hideTitle := rule9 action := rule10 ;; The first matching rule is returned, i. e. the last in the original rder of Config_rule. Break } } Debug_logMessage("DEBUG[6] Manager_applyRules: class: " wndClass ", title: " wndTitle ", wndId: " wndId ", action: " action, 6) } Else { isManaged := False If wndTitle hideTitle := True } } Manager_cleanup() { Local aWndId, m, ncmSize, ncm, wndIds WinGet, aWndId, ID, A Manager_restoreWindowBorders() ;; Show borders and title bars. StringTrimRight, wndIds, Manager_managedWndIds, 1 Manager_hideShow := True Loop, PARSE, wndIds, `; { Window_show(A_LoopField) If Not Config_showBorder Window_set(A_LoopField, "Style", "+0x40000") Window_set(A_LoopField, "Style", "+0xC00000") } ;; Show the task bar. WinShow, Start ahk_class Button WinShow, ahk_class Shell_TrayWnd Manager_hideShow := False ;; Restore window positions and sizes. Loop, % Manager_monitorCount { m := A_Index Monitor_#%m%_showBar := False Monitor_#%m%_showTaskBar := True Monitor_getWorkArea(m) Loop, % Config_viewCount { View_arrange(m, A_Index, True) } } Window_set(aWndId, "AlwaysOnTop", "On") Window_set(aWndId, "AlwaysOnTop", "Off") DllCall("Shell32.dll\SHAppBarMessage", "UInt", (ABM_REMOVE := 0x1), "UInt", &Bar_appBarData) ;; SKAN: Crazy Scripting : Quick Launcher for Portable Apps (http://www.autohotkey.com/forum/topic22398.html) } Manager_closeWindow() { Local aView, aWndId, wndId0, wndIds WinGet, aWndId, ID, A If Window_isProg(aWndId) { ;; Prior to closing, find the next window that should have focus. ;; If there is no such window, choose the bar on the same monitor. aView := Monitor_#%Manager_aMonitor%_aView_#1 StringTrimRight, wndIds, View_#%Manager_aMonitor%_#%aView%_wndIds, 1 StringSplit, wndId, wndIds, `; If (wndId0 >= 2) View_activateWindow(0, +1) Else Manager_winActivate(0) Window_close(aWndId) } } ; Asynchronous management of various WM properties. ; We want to make sure that we can recover the layout and windows in the event of ; unexpected problems. ; Periodically check for changes to these things and save them somewhere (not over ; user-defined files). Manager_doMaintenance: Critical ;; @TODO: Manager_sync? If Not (Config_autoSaveSession = "off") And Not (Config_autoSaveSession = "False") Manager_saveState() Return Manager_getWindowInfo() { Local aWndClass, aWndHeight, aWndId, aWndMinMax, aWndPId, aWndPName, aWndStyle, aWndTitle, aWndWidth, aWndX, aWndY, rule, text, v WinGet, aWndId, ID, A WinGetClass, aWndClass, ahk_id %aWndId% WinGetTitle, aWndTitle, ahk_id %aWndId% WinGet, aWndPName, ProcessName, ahk_id %aWndId% WinGet, aWndPId, PID, ahk_id %aWndId% WinGet, aWndStyle, Style, ahk_id %aWndId% WinGet, aWndMinMax, MinMax, ahk_id %aWndId% WinGetPos, aWndX, aWndY, aWndWidth, aWndHeight, ahk_id %aWndId% text := "ID: " aWndId "`nclass:`t" aWndClass "`ntitle:`t" aWndTitle rule := "Config_rule=" aWndClass ";" aWndTitle ";" If InStr(Manager_managedWndIds, aWndId ";") rule .= ";1" Else rule .= ";0" rule .= ";" Window_#%aWndId%_monitor ";" Window_#%aWndId%_tags ";" Window_#%aWndId%_isFloating ";" Window_#%aWndId%_isDecorated If InStr(Bar_hiddenWndIds, aWndId) { text .= " (hidden)" rule .= ";1;" } Else rule .= ";0;" If (aWndMinMax = 1) rule .= "maximize" text .= "`nprocess:`t" aWndPName " [" aWndPId "]`nstyle:`t" aWndStyle "`nmetrics:`tx: " aWndX ", y: " aWndY ", width: " aWndWidth ", height: " aWndHeight "`ntags:`t" Window_#%aWndId%_tags If Window_#%aWndId%_isFloating text .= " (floating)" text .= "`n`n" rule MsgBox, 260, bug.n: Window Information, % text "`n`nCopy text to clipboard?" IfMsgBox Yes Clipboard := text } Manager_getWindowList() { Local text, v, aWndId, wndIds, aWndTitle v := Monitor_#%Manager_aMonitor%_aView_#1 aWndId := View_#%Manager_aMonitor%_#%v%_aWndId WinGetTitle, aWndTitle, ahk_id %aWndId% text := "Active Window`n" aWndId ":`t" aWndTitle StringTrimRight, wndIds, View_#%Manager_aMonitor%_#%v%_wndIds, 1 text .= "`n`nWindow List" Loop, PARSE, wndIds, `; { WinGetTitle, wndTitle, ahk_id %A_LoopField% text .= "`n" A_LoopField ":`t" wndTitle } MsgBox, 260, bug.n: Window List, % text "`n`nCopy text to clipboard?" IfMsgBox Yes Clipboard := text } Manager_lockWorkStation() { Global Config_shellMsgDelay RegWrite, REG_DWORD, HKEY_CURRENT_USER, Software\Microsoft\Windows\CurrentVersion\Policies\System, DisableLockWorkstation, 0 Sleep, % Config_shellMsgDelay DllCall("LockWorkStation") Sleep, % 4 * Config_shellMsgDelay RegWrite, REG_DWORD, HKEY_CURRENT_USER, Software\Microsoft\Windows\CurrentVersion\Policies\System, DisableLockWorkstation, 1 } ;; Unambiguous: Re-use WIN+L as a hotkey in bug.n (http://www.autohotkey.com/community/viewtopic.php?p=500903&sid=eb3c7a119259b4015ff045ef80b94a81#p500903) Manager_loop(index, increment, lowerBound, upperBound) { If (upperBound <= 0) Or (upperBound < lowerBound) Or (upperBound = 0) Return, 0 numberOfIndexes := upperBound - lowerBound + 1 lowerBoundBasedIndex := index - lowerBound lowerBoundBasedIndex := Mod(lowerBoundBasedIndex + increment, numberOfIndexes) If (lowerBoundBasedIndex < 0) lowerBoundBasedIndex += numberOfIndexes Return, lowerBound + lowerBoundBasedIndex } Manager__setWinProperties(wndId, isManaged, m, tags, isDecorated, isFloating, hideTitle, action = "") { Local a If Not Instr(Manager_allWndIds, wndId ";") Manager_allWndIds .= wndId ";" If (isManaged) { If (action = "close" Or action = "maximize") Window_%action%(wndId) Manager_managedWndIds .= wndId ";" Monitor_moveWindow(m, wndId) Window_#%wndId%_tags := tags Window_#%wndId%_isDecorated := isDecorated Window_#%wndId%_isFloating := isFloating Window_#%wndId%_area := 0 If Not Config_showBorder Window_set(wndId, "Style", "-0x40000") If Not Window_#%wndId%_isDecorated Window_set(wndId, "Style", "-0xC00000") a := Window_#%wndId%_tags & (1 << (Monitor_#%m%_aView_#1 - 1)) If a { ;; A newly created window defines the active monitor, if it is visible. Manager_aMonitor := m Manager_winActivate(wndId) } Else { Manager_hideShow := True Window_hide(wndId) Manager_hideShow := False } } If hideTitle Bar_hideTitleWndIds .= wndId . ";" Return, a } ;; Accept a window to be added to the system for management. ;; Provide a monitor and view preference, but don't override the config. Manager_manage(preferredMonitor, preferredView, wndId) { Local a, action, c0, hideTitle, i, isDecorated, isFloating, isManaged, l, m, n, replace, search, tags, body Local wndControlList0, wndId0, wndIds, wndX, wndY, wndWidth, wndHeight ;; Manage any window only once. If InStr(Manager_allWndIds, wndId ";") Return body := 0 If Window_isGhost(wndId) { Debug_logMessage("DEBUG[2] A window has given up the ghost (Ghost wndId: " . wndId . ")", 2) body := Window_findHung(wndId) If body { isManaged := InStr(Manager_managedWndIds, body ";") m := Window_#%body%_monitor tags := Window_#%body%_tags isDecorated := Window_#%body%_isDecorated isFloating := Window_#%body%_isFloating hideTitle := InStr(Bar_hideTitleWndIds, body ";") action := "" } Else { Debug_logMessage("DEBUG[1] No body could be found for ghost wndId: " . wndId, 1) } } ;; Apply rules if the window is either a normal window or a ghost without a body. If (body = 0) { Manager_applyRules(wndId, isManaged, m, tags, isFloating, isDecorated, hideTitle, action) If (m = 0) m := preferredMonitor If (m < 0) m := 1 If (m > Manager_monitorCount) ;; If the specified monitor is out of scope, set it to the max. monitor. m := Manager_monitorCount If (tags = 0) tags := 1 << (preferredView - 1) } a := Manager__setWinProperties( wndId, isManaged, m, tags, isDecorated, isFloating, hideTitle, action) ; Do view placement. If isManaged { Loop, % Config_viewCount If (Window_#%wndId%_tags & (1 << (A_Index - 1))) { If (body) { ; Try to position near the body. View_ghostWindow(m, A_Index, body, wndId) } Else View_addWindow(m, A_Index, wndId) } } Return, a } Manager_maximizeWindow() { Local aWndId WinGet, aWndId, ID, A If Not Window_#%aWndId%_isFloating View_toggleFloatingWindow(aWndId) Window_set(aWndId, "Top", "") Window_move(aWndId, Monitor_#%Manager_aMonitor%_x, Monitor_#%Manager_aMonitor%_y, Monitor_#%Manager_aMonitor%_width, Monitor_#%Manager_aMonitor%_height) } Manager_moveWindow() { Local aWndId, SC_MOVE, WM_SYSCOMMAND WinGet, aWndId, ID, A If Not Window_#%aWndId%_isFloating View_toggleFloatingWindow(aWndId) Window_set(aWndId, "Top", "") WM_SYSCOMMAND = 0x112 SC_MOVE = 0xF010 SendMessage, WM_SYSCOMMAND, SC_MOVE, , , ahk_id %aWndId% } Manager_onDisplayChange(a, wParam, uMsg, lParam) { Debug_logMessage("DEBUG[1] Manager_onDisplayChange( a: " . a . ", uMsg: " . uMsg . ", wParam: " . wParam . ", lParam: " . lParam . " )", 1) MsgBox, 0x4, , Would you like to reset the monitor configuration? IfMsgBox Yes Manager_resetMonitorConfiguration() } /* Possible indications for a ... new window: 1 (started by Windows Explorer) or 6 (started by cmd, shell or Win+E). There doesn't seem to be a reliable way to get all application starts. closed window: 2 (always?) or 13 (ghost) focus change: 4 or 32772 title change: 6 or 32774 */ Manager_onShellMessage(wParam, lParam) { Local a, isChanged, aWndClass, aWndHeight, aWndId, aWndTitle, aWndWidth, aWndX, aWndY, i, m, t, wndClass, wndId, wndId0, wndIds, wndTitle, x, y ;; HSHELL_* become global. ;; MESSAGE NAME AND ... NUMBER COMMENTS, POSSIBLE EVENTS HSHELL_WINDOWCREATED := 1 ;; window shown HSHELL_WINDOWDESTROYED := 2 ;; window hidden, destroyed or deactivated HSHELL_ACTIVATESHELLWINDOW := 3 HSHELL_WINDOWACTIVATED := 4 ;; window title changed, window activated (by mouse, Alt+Tab or hotkey); alternative message: 32772 HSHELL_GETMINRECT := 5 HSHELL_REDRAW := 6 ;; window title changed HSHELL_TASKMAN := 7 HSHELL_LANGUAGE := 8 HSHELL_SYSMENU := 9 HSHELL_ENDTASK := 10 HSHELL_ACCESSIBILITYSTATE := 11 HSHELL_APPCOMMAND := 12 ;; The following two are seen when a hung window recovers. HSHELL_WINDOWREPLACED := 13 ;; hung window recovered and replaced the ghost window (lParam indicates the ghost window.) HSHELL_WINDOWREPLACING := 14 ;; hung window recovered (lParam indicates the previously hung and now recovered window.) HSHELL_HIGHBIT := 32768 ;; 0x8000 HSHELL_FLASH := 32774 ;; (HSHELL_REDRAW|HSHELL_HIGHBIT); window signalling an application update (The window is flashing due to some event, one message for each flash.) HSHELL_RUDEAPPACTIVATED := 32772 ;; (HSHELL_WINDOWACTIVATED|HSHELL_HIGHBIT); full-screen app or root-privileged window activated? alternative message: 4 ;; Any message may be missed, if bug.n is hung or they come in too quickly. SetFormat, Integer, hex lParam := lParam+0 SetFormat, Integer, d Debug_logMessage("DEBUG[2] Manager_onShellMessage( wParam: " . wParam . ", lParam: " . lParam . " )", 2) WinGetClass, wndClass, ahk_id %lParam% WinGetTitle, wndTitle, ahk_id %lParam% If Not wndClass And Not wndTitle { ;; If there is no window class or title, it is assumed that the window is not identifiable. ;; The problem was, that i. a. claws-mail triggers Manager_sync, but the application window ;; would not be ready for being managed, i. e. class and title were not available. Therefore more ;; attempts were needed. Return } WinGet, aWndId, ID, A WinGetClass, aWndClass, ahk_id %aWndId% WinGetTitle, aWndTitle, ahk_id %aWndId% If ((wParam = 4 Or wParam = 32772) And (aWndClass = "WorkerW" And aWndTitle = "" Or lParam = 0 And aWndClass = "Progman" And aWndTitle = "Program Manager")) { MouseGetPos, x, y m := Monitor_get(x, y) ;; The current position of the mouse cursor defines the active monitor, if the desktop has been activated. If m Manager_aMonitor := m Bar_updateTitle() } ;; This was previously inactive due to `HSHELL_WINDOWREPLACED` not being defined in this function. ;; Afterwards it caused problems managing new windows, when messages come in too quickly. ; If (wParam = HSHELL_WINDOWREPLACED) ; { ;; This shouldn't need a redraw because the window was supposedly replaced. ; Manager_unmanage(lParam) ; } ; If (wParam = 14) ; { ;; Window recovered from being hung. Maybe force a redraw. ; } ;; @todo: There are two problems with the use of Manager_hideShow: ;; 1) If Manager_hideShow is set when we hit this block, we won't take some actions that should eventually be taken. ;; This _may_ explain why some windows never get picked up when spamming Win+e ;; 2) There is a race condition between the time that Manager_hideShow is checked and any other action which we are ;; trying to protect against. If another process (hotkey) enters a hideShow block after Manager_hideShow has ;; been checked here, bad things could happen. I've personally observed that windows may be permanently hidden. ;; Look into the use of AHK synchronization primitives. If (wParam = 1 Or wParam = 2 Or wParam = 4 Or wParam = 6 Or wParam = 32772) And lParam And Not Manager_hideShow And Not Manager_focus { isChanged := Manager_sync(wndIds) If wndIds isChanged := False If isChanged { If Config_dynamicTiling View_arrange(Manager_aMonitor, Monitor_#%Manager_aMonitor%_aView_#1) Bar_updateView(Manager_aMonitor, Monitor_#%Manager_aMonitor%_aView_#1) } If (Manager_monitorCount > 1) { WinGet, aWndId, ID, A WinGetPos, aWndX, aWndY, aWndWidth, aWndHeight, ahk_id %aWndId% m := Monitor_get(aWndX + aWndWidth / 2, aWndY + aWndHeight / 2) Debug_logMessage("DEBUG[1] Manager_onShellMessage: Manager_monitorCount: " Manager_monitorCount ", Manager_aMonitor: " Manager_aMonitor ", m: " m ", aWndId: " aWndId, 1) ;; The currently active window defines the active monitor. If m Manager_aMonitor := m } If wndIds { ;; If there are new (unrecognized) windows, which are hidden ... If (Config_onActiveHiddenWnds = "view") { ;; ... change the view to show the first hidden window wndId := SubStr(wndIds, 1, InStr(wndIds, ";") - 1) Loop, % Config_viewCount { If (Window_#%wndId%_tags & 1 << A_Index - 1) { Debug_logMessage("DEBUG[3] Switching views because " . wndId . " is considered hidden and active", 3) ;; A newly created window defines the active monitor, if it is visible. Manager_aMonitor := Window_#%wndId%_monitor Monitor_activateView(A_Index) Break } } } Else { ;; ... re-hide them StringTrimRight, wndIds, wndIds, 1 StringSplit, wndId, wndIds, `; If (Config_onActiveHiddenWnds = "hide") { Loop, % wndId0 { Window_hide(wndId%A_Index%) } } Else If (Config_onActiveHiddenWnds = "tag") { ;; ... or tag all of them for the current view. t := Monitor_#%Manager_aMonitor%_aView_#1 Loop, % wndId0 { wndId := wndId%A_Index% View_#%Manager_aMonitor%_#%t%_wndIds := wndId ";" View_#%Manager_aMonitor%_#%t%_wndIds View_#%Manager_aMonitor%_#%t%_aWndId := wndId Window_#%wndId%_tags += 1 << t - 1 } Bar_updateView(Manager_aMonitor, t) If Config_dynamicTiling View_arrange(Manager_aMonitor, t) } } } ;; This is a workaround for a redrawing problem of the bug.n bar, which ;; seems to get lost, when windows are created or destroyed under the ;; following conditions. If (Manager_monitorCount > 1) And (Config_verticalBarPos = "tray") { Loop, % (Manager_monitorCount - 1) { i := A_Index + 1 Bar_updateLayout(i) Bar_updateStatic(i) Loop, % Config_viewCount Bar_updateView(i, A_Index) } Bar_updateStatus() Bar_updateTitle() } Else Bar_updateTitle() } } Manager_registerShellHook() { WM_DISPLAYCHANGE := 126 ;; This message is sent when the display resolution has changed. Gui, +LastFound hWnd := WinExist() WinGetClass, wndClass, ahk_id %hWnd% WinGetTitle, wndTitle, ahk_id %hWnd% DllCall("RegisterShellHookWindow", "UInt", hWnd) ;; Minimum operating systems: Windows 2000 (http://msdn.microsoft.com/en-us/library/ms644989(VS.85).aspx) Debug_logMessage("DEBUG[1] Manager_registerShellHook; hWnd: " . hWnd . ", wndClass: " . wndClass . ", wndTitle: " . wndTitle, 1) msgNum := DllCall("RegisterWindowMessage", "Str", "SHELLHOOK") OnMessage(msgNum, "Manager_onShellMessage") OnMessage(WM_DISPLAYCHANGE, "Manager_onDisplayChange") } ;; SKAN: How to Hook on to Shell to receive its messages? (http://www.autohotkey.com/forum/viewtopic.php?p=123323#123323) Manager_resetMonitorConfiguration() { Local GuiN, hWnd, i, m, wndClass, wndIds, wndTitle m := Manager_monitorCount SysGet, Manager_monitorCount, MonitorCount If (Manager_monitorCount < m) { Loop, % m - Manager_monitorCount { i := Manager_monitorCount + A_Index GuiN := (i - 1) + 1 Gui, %GuiN%: Destroy Loop, % Config_viewCount { If View_#%i%_#%A_Index%_wndIds { View_#1_#%A_Index%_wndIds := View_#%i%_#%A_Index%_wndIds View_#1_#%A_Index%_wndIds StringTrimRight, wndIds, View_#%i%_#%A_Index%_wndIds, 1 Loop, PARSE, wndIds, `; { Loop, % Config_viewCount { StringReplace, View_#%i%_#%A_Index%_wndIds, View_#%i%_#%A_Index%_wndIds, %A_LoopField%`;, View_#%i%_#%A_Index%_aWndId := 0 } Monitor_moveWindow(1, A_LoopField) } ;; Manually set the active monitor. Manager_aMonitor := 1 } } } m := Manager_monitorCount } Else If (Manager_monitorCount > m) { Loop, % Manager_monitorCount - m Monitor_init(m + A_Index, True) } Loop, % m { Monitor_getWorkArea(A_Index) Bar_init(A_Index) } Manager_saveState() Loop, % Manager_monitorCount { View_arrange(A_Index, Monitor_#%A_Index%_aView_#1) Bar_updateView(A_Index, Monitor_#%A_Index%_aView_#1) } Manager__restoreWindowState(Main_autoWindowState) Bar_updateStatus() Bar_updateTitle() Gui, +LastFound hWnd := WinExist() WinGetClass, wndClass, ahk_id %hWnd% WinGetTitle, wndTitle, ahk_id %hWnd% DllCall("RegisterShellHookWindow", "UInt", hWnd) ;; Minimum operating systems: Windows 2000 (http://msdn.microsoft.com/en-us/library/ms644989(VS.85).aspx) Debug_logMessage("DEBUG[1] Manager_registerShellHook; hWnd: " . hWnd . ", wndClass: " . wndClass . ", wndTitle: " . wndTitle, 1) } Manager_restoreWindowBorders() { Local ncm, ncmSize If Config_selBorderColor DllCall("SetSysColors", "Int", 1, "Int*", 10, "UInt*", Manager_normBorderColor) If (Config_borderWidth > 0) Or (Config_borderPadding >= 0 And A_OSVersion = WIN_VISTA) { ncmSize := VarSetCapacity(ncm, 4 * (A_OSVersion = WIN_VISTA ? 11 : 10) + 5 * (28 + 32 * (A_IsUnicode ? 2 : 1)), 0) NumPut(ncmSize, ncm, 0, "UInt") DllCall("SystemParametersInfo", "UInt", 0x0029, "UInt", ncmSize, "UInt", &ncm, "UInt", 0) If (Config_borderWidth > 0) NumPut(Manager_borderWidth, ncm, 4, "Int") If (Config_borderPadding >= 0 And A_OSVersion = WIN_VISTA) NumPut(Manager_borderPadding, ncm, 40 + 5 * (28 + 32 * (A_IsUnicode ? 2 : 1)), "Int") DllCall("SystemParametersInfo", "UInt", 0x002a, "UInt", ncmSize, "UInt", &ncm, "UInt", 0) } } ;; Restore previously saved window state. ;; If the state is completely different, this function won't do much. However, if restoring from a crash ;; or simply restarting bug.n, it should completely recover the window state. Manager__restoreWindowState(filename) { Local vidx, widx, i, j, m, v, candidate_set, detectHidden, view_set, excluded_view_set, view_m0, view_v0, view_list0, wnds0, items0, wndPName, view_var, isManaged, isFloating, isDecorated, hideTitle If Not FileExist(filename) Return widx := 1 vidx := 1 view_set := "" excluded_view_set := "" ;; Read all interesting things from the file. Loop, READ, %filename% { If (SubStr(A_LoopReadLine, 1, 5) = "View_") { i := InStr(A_LoopReadLine, "#") j := InStr(A_LoopReadLine, "_", false, i) m := SubStr(A_LoopReadLine, i + 1, j - i - 1) i := InStr(A_LoopReadLine, "#", false, j) j := InStr(A_LoopReadLine, "_", false, i) v := SubStr(A_LoopReadLine, i + 1, j - i - 1) i := InStr(A_LoopReadLine, "=", j + 1) If (m <= Manager_monitorCount) And ( v <= Config_viewCount ) { view_list%vidx% := SubStr(A_LoopReadLine, i + 1) view_m%vidx% := m view_v%vidx% := v view_set := view_set . view_list%vidx% vidx := vidx + 1 } Else { excluded_view_set := excluded_view_set . view_list%vidx% Debug_logMessage("View (" . m . ", " . v . ") is no longer available (" . vidx . ")", 0) } } Else If (SubStr(A_LoopReadLine, 1, 7) = "Window ") { wnds%widx% := SubStr(A_LoopReadLine, 8) widx := widx + 1 } } ;Debug_logMessage("view_set: " . view_set, 1) ;Debug_logMessage("excluded_view_set: " . excluded_view_set, 1) candidate_set := "" ; Scan through all defined windows. Create a candidate set of windows based on whether the properties of existing windows match. Loop, % (widx - 1) { StringSplit, items, wnds%A_Index%, `; If (items0 < 9) { Debug_logMessage("Window '" . wnds%A_Index% . "' could not be processed due to parse error", 0) Continue } i := 1 i := items%i% j := 2 detectHidden := A_DetectHiddenWindows DetectHiddenWindows, On WinGet, wndPName, ProcessName, ahk_id %i% DetectHiddenWindows, %detectHidden% If Not ( items%j% = wndPName ) { Debug_logMessage("Window ahk_id " . i . " process '" . wndPName . "' doesn't match expected '" . items%j% . "', forgetting this window", 0) Continue } j := 8 isManaged := items%j% ; If Managed If ( items%j% ) { If ( InStr(view_set, i) = 0) { If ( InStr(excluded_view_set, i) ) Debug_logMessage("Window ahk_id " . i . " is being ignored because it no longer belongs to an active view", 0) Else Debug_logMessage("Window ahk_id " . i . " is being ignored because it doesn't exist in any views", 0) Continue } } ; Set up the window. j := 3 m := items%j% j := 4 v := items%j% j := 5 isFloating := items%j% j := 6 isDecorated := items%j% j := 7 hideTitle := items%j% Manager__setWinProperties(i, isManaged, m, v, isDecorated, isFloating, hideTitle ) ;Window_hide(i) candidate_set := candidate_set . i . ";" } ;Debug_logMessage("candidate_set: " . candidate_set, 1) ; Set up all views. Must filter the window list by those from the candidate set. Loop, % (vidx - 1) { StringSplit, items, view_list%A_Index%, `; view_set := "" Loop, % (items0 - 1) { If ( InStr(candidate_set, items%A_Index% ) > 0 ) view_set := view_set . items%A_Index% . ";" } view_var := "View_#" . view_m%A_Index% . "_#" . view_v%A_Index% . "_wndIds" %view_var% := view_set } } Manager_saveState() { Critical Global Config_filePath, Config_viewCount, Main_autoLayout, Main_autoWindowState, Manager_layoutDirty, Manager_monitorCount, Manager_windowsDirty Debug_logMessage("DEBUG[2] Manager_saveState", 2) ;; @TODO: Check for changes to the layout. ;If Manager_layoutDirty { Debug_logMessage("DEBUG[2] Manager_saveState: " Main_autoLayout, 2) Config_saveSession(Config_filePath, Main_autoLayout) Manager_layoutDirty := 0 ;} ;; @TODO: Check for changes to windows. ;If Manager_windowsDirty { Debug_logMessage("DEBUG[2] Manager_saveState: " Main_autoWindowState, 2) Manager_saveWindowState(Main_autoWindowState, Manager_monitorCount, Config_viewCount) Manager_windowsDirty := 0 ;} } Manager_saveWindowState(filename, nm, nv) { Local allWndId0, allWndIds, detectHidden, wndPName, title, text, monitor, wndId, view, isManaged, isTitleHidden text := "; bug.n - tiling window management`n; @version " VERSION "`n`n" tmpfname := filename . ".tmp" FileDelete, %tmpfname% ; Dump window ID and process name. If these two don't match an existing process, we won't try ; to recover that window. StringTrimRight, allWndIds, Manager_allWndIds, 1 StringSplit, allWndId, allWndIds, `; detectHidden := A_DetectHiddenWindows DetectHiddenWindows, On Loop, % allWndId0 { wndId := allWndId%A_Index% WinGet, wndPName, ProcessName, ahk_id %wndId% ; Include title for informative reasons. WinGetTitle, title, ahk_id %wndId% ; wndId;processName;Tags;Floating;Decorated;HideTitle;Managed;Title isManaged := InStr(Manager_managedWndIds, wndId . ";") isTitleHidden := InStr(Bar_hideTitleWndIds, wndId . ";") text .= "Window " . wndId . ";" . wndPName . ";" . Window_#%wndId%_monitor . ";" . Window_#%wndId%_tags . ";" . Window_#%wndId%_isFloating . ";" . Window_#%wndId%_isDecorated . ";" . isTitleHidden . ";" . isManaged . ";" . title . "`n" } DetectHiddenWindows, %detectHidden% text .= "`n" ;; Dump window arrangements on every view. If some views or monitors have disappeared, leave their ;; corresponding windows alone. Loop, % nm { monitor := A_Index Loop, % nv { view := A_Index ;; Dump all view window lists text .= "View_#" . monitor . "_#" . view . "_wndIds=" . View_#%monitor%_#%view%_wndIds . "`n" } } FileAppend, %text%, %tmpfname% If ErrorLevel { If FileExist(tmpfname) FileDelete, %tmpfname% } Else FileMove, %tmpfname%, %filename%, 1 } Manager_setCursor(wndId) { Local wndHeight, wndWidth, wndX, wndY If Config_mouseFollowsFocus { If wndId { WinGetPos, wndX, wndY, wndWidth, wndHeight, ahk_id %wndId% DllCall("SetCursorPos", "Int", Round(wndX + wndWidth / 2), "Int", Round(wndY + wndHeight / 2)) } Else DllCall("SetCursorPos", "Int", Round(Monitor_#%Manager_aMonitor%_x + Monitor_#%Manager_aMonitor%_width / 2), "Int", Round(Monitor_#%Manager_aMonitor%_y + Monitor_#%Manager_aMonitor%_height / 2)) } } Manager_setViewMonitor(i, d = 0) { Local aView, aWndId, v, wndIds aView := Monitor_#%Manager_aMonitor%_aView_#1 If (Manager_monitorCount > 1) And View_#%Manager_aMonitor%_#%aView%_wndIds { If (i = 0) i := Manager_aMonitor i := Manager_loop(i, d, 1, Manager_monitorCount) v := Monitor_#%i%_aView_#1 View_#%i%_#%v%_wndIds := View_#%Manager_aMonitor%_#%aView%_wndIds View_#%i%_#%v%_wndIds StringTrimRight, wndIds, View_#%Manager_aMonitor%_#%aView%_wndIds, 1 Loop, PARSE, wndIds, `; { Loop, % Config_viewCount { StringReplace, View_#%Manager_aMonitor%_#%A_Index%_wndIds, View_#%Manager_aMonitor%_#%A_Index%_wndIds, %A_LoopField%`;, View_#%Manager_aMonitor%_#%A_Index%_aWndId := 0 } Monitor_moveWindow(i, A_LoopField) Window_#%A_LoopField%_tags := 1 << v - 1 } View_arrange(Manager_aMonitor, aView) Loop, % Config_viewCount { Bar_updateView(Manager_aMonitor, A_Index) } ;; Manually set the active monitor. Manager_aMonitor := i View_arrange(i, v) WinGet, aWndId, ID, A Manager_winActivate(aWndId) Bar_updateView(i, v) } } Manager_setWindowBorders() { Local ncm, ncmSize If Config_selBorderColor { SetFormat, Integer, hex Manager_normBorderColor := DllCall("GetSysColor", "Int", 10) SetFormat, Integer, d DllCall("SetSysColors", "Int", 1, "Int*", 10, "UInt*", Config_selBorderColor) } If (Config_borderWidth > 0) Or (Config_borderPadding >= 0 And A_OSVersion = WIN_VISTA) { ncmSize := VarSetCapacity(ncm, 4 * (A_OSVersion = WIN_VISTA ? 11 : 10) + 5 * (28 + 32 * (A_IsUnicode ? 2 : 1)), 0) NumPut(ncmSize, ncm, 0, "UInt") DllCall("SystemParametersInfo", "UInt", 0x0029, "UInt", ncmSize, "UInt", &ncm, "UInt", 0) Manager_borderWidth := NumGet(ncm, 4, "Int") Manager_borderPadding := NumGet(ncm, 40 + 5 * (28 + 32 * (A_IsUnicode ? 2 : 1)), "Int") If (Config_borderWidth > 0) NumPut(Config_borderWidth, ncm, 4, "Int") If (Config_borderPadding >= 0 And A_OSVersion = WIN_VISTA) NumPut(Config_borderPadding, ncm, 40 + 5 * (28 + 32 * (A_IsUnicode ? 2 : 1)), "Int") DllCall("SystemParametersInfo", "UInt", 0x002a, "UInt", ncmSize, "UInt", &ncm, "UInt", 0) } } Manager_setWindowMonitor(i, d = 0) { Local aWndId, v WinGet, aWndId, ID, A If (Manager_monitorCount > 1 And InStr(Manager_managedWndIds, aWndId ";")) { Loop, % Config_viewCount { StringReplace, View_#%Manager_aMonitor%_#%A_Index%_wndIds, View_#%Manager_aMonitor%_#%A_Index%_wndIds, %aWndId%`;, If (aWndId = View_#%Manager_aMonitor%_#%A_Index%_aWndId) View_#%Manager_aMonitor%_#%A_Index%_aWndId := 0 Bar_updateView(Manager_aMonitor, A_Index) } If Config_dynamicTiling View_arrange(Manager_aMonitor, Monitor_#%Manager_aMonitor%_aView_#1) ;; Manually set the active monitor. If (i = 0) i := Manager_aMonitor Manager_aMonitor := Manager_loop(i, d, 1, Manager_monitorCount) Monitor_moveWindow(Manager_aMonitor, aWndId) v := Monitor_#%Manager_aMonitor%_aView_#1 Window_#%aWndId%_tags := 1 << v - 1 View_#%Manager_aMonitor%_#%v%_wndIds := aWndId ";" View_#%Manager_aMonitor%_#%v%_wndIds View_#%Manager_aMonitor%_#%v%_aWndId := aWndId If Config_dynamicTiling View_arrange(Manager_aMonitor, v) Manager_winActivate(aWndId) Bar_updateView(Manager_aMonitor, v) } } Manager_sizeWindow() { Local aWndId, SC_SIZE, WM_SYSCOMMAND WinGet, aWndId, ID, A If Not Window_#%aWndId%_isFloating View_toggleFloatingWindow(aWndId) Window_set(aWndId, "Top", "") WM_SYSCOMMAND = 0x112 SC_SIZE = 0xF000 SendMessage, WM_SYSCOMMAND, SC_SIZE, , , ahk_id %aWndId% } ;; No windows are known to the system yet. ;; Try to do something smart with the initial layout. Manager_initial_sync(doRestore) { Local wndId, wndId0, wnd, wndX, wndY, wndW, wndH, x, y, m, len ;; Initialize lists ;; Note that these variables make this function non-reentrant. Loop, % Manager_monitorCount Manager_initial_sync_m#%A_Index%_wndList := "" ;; Use saved window placement settings to first determine ;; which monitor/view a window should be attached to. If doRestore Manager__restoreWindowState(Main_autoWindowState) ;; Check all remaining visible windows against the known windows WinGet, wndId, List, , , Loop, % wndId { ;; Based on some analysis here, determine which monitors and layouts would best ;; serve existing windows. Do not override configuration settings. ;; Which monitor is it on? wnd := wndId%A_Index% WinGetPos, wndX, wndY, wndW, wndH, ahk_id %wnd% x := wndX + wndW/2 y := wndY + wndH/2 m := Monitor_get(x, y) If m > 0 Manager_initial_sync_m#%m%_wndList .= wndId%A_Index% ";" } Loop, % Manager_monitorCount { m := A_Index StringTrimRight, wndIds, Manager_initial_sync_m#%m%_wndList, 1 StringSplit, wndId, wndIds, `; Loop, % wndId0 Manager_manage(m, 1, wndId%A_Index%) } } ;; @todo: This constantly tries to re-add windows that are never going to be manageable. ;; Manager_manage should probably ignore all windows that are already in Manager_allWndIds. ;; The problem was, that i. a. claws-mail triggers Manager_sync, but the application window ;; would not be ready for being managed, i. e. class and title were not available. Therefore more ;; attempts were needed. ;; Perhaps this method can be refined by not adding any window to Manager_allWndIds, but only ;; those, which have at least a title or class. Manager_sync(ByRef wndIds = "") { Local a, flag, shownWndIds, v, visibleWndIds, wndId Loop, % Manager_monitorCount { v := Monitor_#%A_Index%_aView_#1 shownWndIds .= View_#%A_Index%_#%v%_wndIds } ;; Check all visible windows against the known windows WinGet, wndId, List, , , Loop, % wndId { If Not InStr(shownWndIds, wndId%A_Index% ";") { If Not InStr(Manager_managedWndIds, wndId%A_Index% ";") { flag := Manager_manage(Manager_aMonitor, Monitor_#%Manager_aMonitor%_aView_#1, wndId%A_Index%) If flag a := flag } Else If Not Window_isHung(wndId%A_Index%) { ;; This is a window that is already managed but was brought into focus by something. ;; Maybe it would be useful to do something with it. wndIds .= wndId%A_Index% ";" } } visibleWndIds := visibleWndIds wndId%A_Index% ";" } ;; @todo-future: Find out why this unmanage code exists and if it's still needed. ;; check, if a window, that is known to be visible, is actually not visible StringTrimRight, shownWndIds, shownWndIds, 1 Loop, PARSE, shownWndIds, `; { If Not InStr(visibleWndIds, A_LoopField) { flag := Manager_unmanage(A_LoopField) If flag a := flag } } Return, a } Manager_unmanage(wndId) { Local a, aView, wndId0, wndIds ;; Find the next window that should have focus. ;; If there is no such window, choose the bar on the same monitor. aView := Monitor_#%Manager_aMonitor%_aView_#1 StringTrimRight, wndIds, View_#%Manager_aMonitor%_#%aView%_wndIds, 1 StringSplit, wndId, wndIds, `; If (wndId0 >= 2) View_activateWindow(0, +1) Else Manager_winActivate(0) ;; Do our best to make sure that any unmanaged windows are left visible. Window_show(wndId) a := Window_#%wndId%_tags & 1 << aView - 1 Loop, % Config_viewCount { If (Window_#%wndId%_tags & 1 << A_Index - 1) { StringReplace, View_#%Manager_aMonitor%_#%A_Index%_wndIds, View_#%Manager_aMonitor%_#%A_Index%_wndIds, %wndId%`;, Bar_updateView(Manager_aMonitor, A_Index) } } Window_#%wndId%_monitor := Window_#%wndId%_tags := Window_#%wndId%_isDecorated := Window_#%wndId%_isFloating := Window_#%wndId%_area := StringReplace, Bar_hideTitleWndIds, Bar_hideTitleWndIds, %wndId%`;, StringReplace, Manager_allWndIds, Manager_allWndIds, %wndId%`;, StringReplace, Manager_managedWndIds, Manager_managedWndIds, %wndId%`;, , All Return, a } Manager_winActivate(wndId) { Manager_setCursor(wndId) Debug_logMessage("DEBUG[1] Activating window: " wndId, 1) If Not wndId { If (A_OSVersion = "WIN_8") WinGet, wndId, ID, ahk_class WorkerW Else WinGet, wndId, ID, Program Manager ahk_class Progman Debug_logMessage("DEBUG[1] Activating Desktop: " wndId, 1) } If Window_activate(wndId) Return, 1 Else { Bar_updateTitle() Return 0 } }